*Hypersil ODS (C18)
Provide an excellent C18 phase for a broad range of applications and global standard for many existing methods.
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
10% |
2-8 |
L1 |
|
*Hypersil ODS-2 (C18)
Offer a well tested, dependable L1 alternative to many older column brands commonly referenced in validated methods.
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
80Å |
11% |
2-8 |
L1 |
|
*Hypersil MOS and MOS-2 (C8)
Have a monolayer coverage of C8 alkyl chain chemically bonded onto the silica surface for a reproducible and
efficient stationary phase.
- Hypersil MOS-2 is endcapped
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
6.5% |
2-8 |
L7 |
|
*Hypersil SAS (C1)
The least retentive of the Hypersil alkyl bonded phases.
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
2.5% |
2-8 |
L13 |
|
*Hypersil Phenyl and Phenyl-2
Reversed phase materials with selectivity for the analysis of aromatic and moderately polar compounds.
- Hypersil Phenyl-2 is endcapped
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
5% |
2-8 |
L11 |
|
*Hypersil CPS and CPS-2 (Cyano)
A cyanopropyl phase for both normal and reversed phase HPLC.
- Hypersil CPS-2 is endcapped
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
4% |
2-8 |
L10 |
|
*Hypersil APS-2
Versatile amino propyl phase.
- In reversed phase mode, Hypersil APS-2 columns are excellent for carbohydrate analysis: extra sensitivity for sugars
- Alternative selectivity to silica when used in normal phase
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
1.9% |
2.5-8 |
L8 |
|
*Hypersil Silica
An unbonded media serves as an efficient tool for normal phase chromatography of nonpolar and moderately polar organic compounds.
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
- |
2-8 |
L3 |
|
*Hypersil SAX
Highly stable silica-based quarternary amine strong anion exchange columns, designed for aqueous and low pH mobile phases.
- Weak anion exchange phase for multiple charged species
- Suitable for HILIC retention and separation of highly polar molecules
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
1.9, 3, 5 μm |
175Å |
6% |
2-8 |
- |
|
*Hypersil Green PAH
Specially tailored alkyl bonded silica with a high carbon loading, designed specifically for the analysis of polyaromatic hydrocarbons (PAHs).
- Optimized for EPA Method 610
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
13.5% |
2-9 |
- |
|