*Acclaim AmG C18
Designed to provide rugged and reproducible reversed-phase chromatography of aminoglycoside antibiotics.
- Easy to use with only aqueous mobile phase; TFA only, or TFA/HFBA or PFPA is needed
- Compatible with simple rugged methods; no solvents are required
|
*Acclaim Trinity P1
Mixed mode column technology combining reversed-phase, anion exchange and cation exchange functionality on a single support.
- Ideal selectivity for simultaneous separation of API and counterion
- Adjustable selectivity by mobile phase ionic strength, electrolyte type, pH, and organic solvent
- Low bleed; compatible with MS, CAD and ELSD
|
*Acclaim Trinity P2
Mixed-mode column technology; hydrophilic interaction combining HILIC,anion exchange and cation exchange functionalities.
- Ideal for separating pharmaceutical counterions, including monovalent and divalent cations or anions
- Selectivity complementary to the Trinity P1 column
- Low column bleed, compatible with CAD and MS
|
*Acclaim Organic Acid
Optimized and application-tested for the analysis of hydrophilic organic acids.
- Compatible with 100% aqueous mobile phases
- Hydrolytic stability at low-pH conditions
|
*Acclaim Surfactant
Excellent performance for separating a broad range of surfactants.
- Ideal selectivity for separation of anionic, nonionic, cationic and amphoteric surfactants
- Compatible with highly aqueous mobile phases
|
*Acclaim Surfactant Plus
Column of choice for surfactant analysis using higher sensitivity detection: performance, versatility, throughput.
- Ideal selectivity for simultaneous separation of anionic, nonionic, cationic,and amphoteric surfactants
- Compatible with multiple detectors including MS, CAD, ELSD and UV
|
*Acclaim Explosives E2
The best solution for explosives analysis (EPA Method 8330).
- Acclaim E2 columns provide baseline resolution of all 14 compounds targeted by EPA Method 8330
- Columns available in 2.2, 3 and 5μm particle size
- Simple isocratic elution conditions
|
*Acclaim Trinity Q1
For trace analysis of diquat and paraquat.
- LC-MS compatible
- No ion-pairing reagent needed
|
*Acclaim Carbamate
Designed for baseline separation of carbamate pesticides specified in US EPA Method 531.2.
- Use with either LC/postcolumn derivatization/fluorescence or LC-MS detection
- Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) mobile phase gradients
|
*Acclaim Carbonyl C18
A silica-based, reversed-phase column designed specifically for separating DNPH derivatives of aldehydes and ketones.
- Ideal selectivity for baseline resolution of DNPH derivatives of aldehydes and ketones regulated by various official methods, including EPA 554,
EPA 8315, EPA 1667, EPA TO-11, and CARB 1004
|