Shodex
之各式分離管口碑極佳,
其中GPC / GFC (SEC) Column
更是代表作。
現在我們以很合理之價格引進,歡迎來電洽購。
GEL PERMEATION CHROMATOGRAPHY(有機相) COLUMNS
■
STANDARD
TYPE COLUMNS
|
In-column
solvents
|
Exclusion Limit
(PS/PEG)2
|
Plate
number
|
ID x Length
(mm)
|
|
|
THF
|
Chloroform
|
DMF
|
|
GPC KF-801
|
GPC K-801
|
GPC KD-801
|
1,5003
|
>16,000
|
8.0 x 300
|
THF: Most commonly used for GPC.
Chloroform: Also commonly used for GPC.
DMF
(dimethylformamide): Used for analysis of polar samples such as
melamine and phenol resins. SB-800 HQ series and GF. HQ series can also be used with DMF
P.S.
1:
Renamed from “80M” to “806M”
2: For KF-800 and K-800, PS
(polysty-rene) is
used with THF.
For KD-800, PEG (polyethylene glycol) is used with DMF.
3:
In case of KD-801, exclusion limit is 2,500.
4: Figures in parentheses are estimated values.
|
|
GPC KF-802
|
GPC K-802
|
GPC KD-802
|
5,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-802.5
|
GPC K-802.5
|
GPC KD-802.5
|
20,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-803
|
GPC K-803
|
GPC KD-803
|
70,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-803L
|
GPC K-803L
|
|
70,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-804
|
GPC K-804
|
GPC KD-804
|
400,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-804L
|
GPC K-804L
|
|
400,000
|
>16,000
|
8.0 x 300
|
|
GPC KF-805
|
GPC K-805
|
GPC KD-805
|
4,000,000
|
>10,000
|
8.0 x 300
|
|
GPC KF-805L
|
GPC K-805L
|
|
4,000,000
|
>10,000
|
8.0 x 300
|
|
GPC KF-806
|
GPC K-806
|
GPC KD-806
|
(20,000,000)4
|
>10,000
|
8.0 x 300
|
|
GPC KF-806M1
|
GPC K-806M1
|
GPC KD-806M1
|
(20,000,000)4
|
>12,000
|
8.0 x 300
|
|
GPC KF-806L
|
GPC K-806L
|
|
(20,000,000)4
|
>10,000
|
8.0 x 300
|
|
GPC KF-807
|
GPC K-807
|
GPC KD-807
|
(200,000,000)4
|
>5,000
|
8.0 x 300
|
|
GPC KF-807L
|
GPC K-807L
|
|
(200,000,000)4
|
>5,000
|
8.0 x 300
|
|
GPC KF-G (KF-800P)
|
GPC K-G (K-800P)
|
GPC KD-G (KD-800P)
|
(guard
column)
|
|
4.6 x 10
|
The columns which have “ L “ at the end the column name are linear
type columns. Linear type columns are specially designed to have wide
linear range in molecular weight calibration curves from oligomers to
macromolecules. Linear type columns are highly recommended for
correcting non-linear sections of molecular weight calibration curves of
ordinary columns. It is
generally recommended that a linear type rather than an ordinary type be
used when both of them are available.
■
DOWNSIZED GPC COLUMNS
Please
consult us.
■
SOLVENT-PEAK SEPARATION COLUMNS
Please
consult us.
■
HFIP PACKED COLUMNS
HFIP columns are packed with HFIP
(hexafluoroiso propanol) solvent. Engineering plastics, such as polyamides (nylon) and
PET (polyethylene tereph thalate) were formerly analyzed at high
temperature, about 150℃.
■
DOWNSIZED HFIP PACKED COLUMNS
Please
consult us.
■
HIGH TEMPERATURE GPC COLUMNS
Please
consult us.
|
CALIBRATION CURVES FOR
KF-800 SERIES

Column
: Shodex GPC
KF-800 series
Eluent
: THF
|
CALIBRATION
CURVES FOR
KF-800L (LINEAR TYPE) SERIES

Column
: Shodex GPC KF-800L
series and KF-806M
Eluent
: THF
|
CALIBRATION
CURVES FOR
KD-800 SERIES

Column
: Shodex KD-800 series
Eluent
: DMF
|

GEL
FILTRATON CHROMATOGRAPHY(SEC,水相)
COLUMNS
|
Column type
|
Exclusion Limit
|
Usable
pH range
|
Plate
number
|
ID x Length
(mm)
|
Application
|
|
(Pullulan)
|
(Proteins)
|
|
OHpak SB-802 HQ
OHpak SB-802.5 HQ
OHpak SB-803 HQ
OHpak SB-804 HQ
OHpak SB-805 HQ
OHpak SB-806 HQ
OHpak SB-806M HQ
OHpak
SB-G (SB-800P)
|
4,000
10,000
100,000
1,000,000
4,000,000
20,000,0001
20,000,0001
(
guard column)
|
|
3~10
3~10
3~10
3~10
3~10
3~10
3~10
|
>10,000
>15,000
>15,000
>15,000
>10,000
>10,000
>10,000
|
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
6.0 x 050
|
Polyhydroxy-
methacrylate polymer-based columns
As general-purpose
GFC/SEC columns, suited for
analyses of water-soluble polymers, proteins and enzymes.
|
|
PROTEIN KW-802.5
PROTEIN KW-803
PROTEIN KW-804
PROTEIN KW-604S
PROTEIN
KW-G (KW-800P)
|
60,000
170,000
500,000
500,000
(guard column)
|
150,000
700,000
1,000,000
1,000,000
|
3~7.5
3~7.5
3~7.5
3~7.5
|
>20,000
>20,000
>10,000
|
8.0 x 300
8.0 x 300
8.0 x 300
6.0 x 050
6.0 x 050
|
Packed with silica-based gels and has a pore structure
suited for protein separation.
KW-604S is suited to eliminate proteins from the
sample by column-switching.
|
1 :
Figures in paretheses are estimated values.

MULTIMODE COLUMNS
|
Column
type
|
Exclustion
limit
(Pullulan)
|
Usable
pH
range
|
Plate
number
|
ID
x Length
(mm)
|
Applications
|
|
Asahipak
GS-220 HQ
Asahipak
GS-320 HQ
Asahipak
GS-520 HQ
Asahipak
GS-620 HQ
Asahipak
GS-2G 7B
|
3,000
40,000
300,000
1,000,000
(guard
column)
|
2
~ 9
2
~ 12
2
~ 12
2
~ 9
|
>16,000
>16,000
>15,000
>15,000
|
7.6
x 300
7.6
x 300
7.6
x 300
7.6
x 300
7.6
x 050
|
multimode
analyses GFC/SEC columns (mixed mode of size exclusion, ion
exchange and partition & adsorption)
|

MULTISOLVENT
GPC COLUMNS
|
Column type
|
Exclustion limit
(Pullulan) |
Usable
pH range |
Plate
number |
ID x Length
(mm) |
both GPC (organic GPC) and GFC
(aqueous
GPC) can be performed with
one column.
|
Example
of usable solvents
|
|
Water
with salt
|
0~0.5M
|
○
|
|
Methanol
|
0~100%
|
○
|
|
Ethanol
|
0~100%
|
○
|
|
Acetonitrile
|
0~100%
|
○
|
|
THF
|
0~100%
|
○
|
|
DMF
|
0~100%
|
○
|
|
Acetone
|
0~100%
|
○
|
|
Chloroform
|
0~100%
|
○
|
|
Ethyl
acetate
|
0~100%
|
○
|
|
DMSO
|
0~050%
|
○
|
|
DMSO
|
.51~100%
|
×
|
○:usable
×: unusable |
|
Asahipak GF-310 HQ
Asahipak GF-510 HQ
Asahipak GF-710 HQ
Asahipak GF-7M HQ
Asahipak
GF-1G 7B
|
40,000
300,000
10,000,000
10,000,000
(guard column)
|
2 ~ 9
2 ~ 9
2 ~ 9
2 ~ 9
|
>16,000
>16,000
>10,000
>11,000
|
7.6 x 300
7.6 x 300
7.6 x 300
7.6 x 300
7.6 x 050
|
|
CALIBRATION CURVES FOR
CALIBRATION CURVES FOR
SB-800HQ SERIES
KW-800 SERIES
 
|
Column : Shodex OHpak SB-800HQ series
Eluent :
H2O
|
Column :
Shodex PROTEIN KW series
Eluent : 0.1M Sodium phoshate
(pH7.0)
|
|
|